Advanced Search

SUN Ming liang. Measurement Technology of Noble Gas Isotopes in Natural Gases[J]. Acta Sedimentologica Sinica, 2001, 19(2): 271-272.
Citation: SUN Ming liang. Measurement Technology of Noble Gas Isotopes in Natural Gases[J]. Acta Sedimentologica Sinica, 2001, 19(2): 271-272.

Measurement Technology of Noble Gas Isotopes in Natural Gases

  • Received Date: 2000-09-25
  • A high vacuum purification line with lower leakage and lower background level had been established.The contamination of atmospheric argon to the samples was eliminated.The author determined the40/36Ar ratios of the samples analyzed previously using new method. Precise sup>40/36Ar ratio is obtained by this system.The sup>40/36Ar ratio observed by the new method is significantly higher than the previously determined ones, and the discrepancy was related to the Ar content of nature gas.Separating Ar from Kr and Xe is basically successful by temperature-modulated cold finger Kr and Xe isotopic compositions then can he measured.
  • [1] 1 孙明良,徐永昌,王先彬. 天然气中氦同位素的质谱分析[J]. 分析测试通报,1991,5:50 ~ 55

    2 孙明良,陶明信. 天然气氦同位素分布与大地构造环境[J]. 兰州大学学报(自然科学版),1993,29(4):247 ~ 251

    3 徐永昌,沈平,刘文汇,陶明信,孙明良,杜建国. 天然气中稀有气体地球化学[M]. 北京:科学出版社,1998

    4 戴金星,宋岩,戴春森,陈安福,孙明良,廖永胜. 中国东部无机成因气及其成藏形成条件[M]. 北京:科学出版社,1995

    5 O'nions R K,Oxburgh E R. Helium,volatile fluxes and the development of continental crus[t J]. Earth Plant Sci. Lett.1988,90:331 ~ 347

    6 Sheng Xu et al. Mantie-derived nobie gases in naturai gases from SongliaoBasin,China[J].Geochimica et Cosmochimica Acta,1995,59:4 675 ~ 4 683
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article Metrics

Article views(539) PDF downloads(684) Cited by()

Proportional views
Related
Publishing history
  • Received:  2000-09-25

Measurement Technology of Noble Gas Isotopes in Natural Gases

Abstract: A high vacuum purification line with lower leakage and lower background level had been established.The contamination of atmospheric argon to the samples was eliminated.The author determined the40/36Ar ratios of the samples analyzed previously using new method. Precise sup>40/36Ar ratio is obtained by this system.The sup>40/36Ar ratio observed by the new method is significantly higher than the previously determined ones, and the discrepancy was related to the Ar content of nature gas.Separating Ar from Kr and Xe is basically successful by temperature-modulated cold finger Kr and Xe isotopic compositions then can he measured.

SUN Ming liang. Measurement Technology of Noble Gas Isotopes in Natural Gases[J]. Acta Sedimentologica Sinica, 2001, 19(2): 271-272.
Citation: SUN Ming liang. Measurement Technology of Noble Gas Isotopes in Natural Gases[J]. Acta Sedimentologica Sinica, 2001, 19(2): 271-272.
Reference (1)

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return